Overview

The Cleaver Brooks 4WG model is a skid-mounted packaged boiler complete with the boiler, burner, and all required controls and safety equipment. The 4WG is a four-pass wet-back firetube boiler, constructed to ASME Section I code and utilizing 5 sq ft of surface area per boiler horsepower. This particular unit is designed and built to operate with low emissions (30 ppm) while maintaining the high fuel to steam efficiency that Cleaver Brooks boilers are known for.

This boiler was purchased by Powerhouse from a customer who was replacing these boilers with new ones. This boiler has since been fully reconditioned and tested for a new customer. Our reconditioning process verifies that this boiler is 100% functional and ready for many more years of service which is why we offer a 1-yr warranty that matches or exceeds the original factory warranty.

Specs

  • BrandCleaver Brooks
  • Boiler TypeFiretube
  • Output Capacity3,019 - 24,150 PPH
  • Max Pressure75 - 150 PSIG
  • Fuel(s)#2 Oil, Natural Gas
  • ServiceSaturated Steam
  • Emission Rating30 ppm

Technical Specifications

General Design

  • Manufacturer (OEM)Cleaver-Brooks
  • Year 2005
  • Serial No.OL104175
  • National Board No.14070
  • CRN No.-
  • Model4WG-200-700-150
  • TypeScotch
  • DesignFour-Pass Wet Back Firetube
  • MountingSaddles & Skid-Mounted
  • InternalCorrugated Furnace & Straight Tubes

Capacities & Inputs

  • Output Capacity24,150 LBS/HR
  • Horsepower700 BHP
  • Design Pressure (MAWP)150 PSIG
  • Operating Range75-140 PSIG
  • Heating Surface3,500 FT²
  • Max. Fuel InputNG: 29,300,000 BTU/HR #2: 209 GPH
  • Standard FuelsNatural Gas & #2 Fuel Oil
  • Additional Fuels
  • Input Gas PressureMin: 4.8 PSIG
  • Turndown RatiosNG: 8:1 #2: 6:1
  • Emission Rating (NOX)NG: 30 PPM #2: 75 PPM

Burner and Electrical

  • Burner Manufacturer (OEM)Cleaver-Brooks
  • ModelLNDLG-378P
  • TypeFull Modulation
  • Flue Gas Recirculation (FGR)Yes
  • Electric460V/3PH/60Hz
  • AtomizationAir
  • Control TypeSingle Point Positioning
  • Boiler Control System-
  • Burner Management SystemHoneywell RM7800
  • Flame SafeguardUV Scanner
  • Blow Motor75 HP
  • Burner Installed Yes
  • Pilot TypeInterrupted Gas
  • Instrument AirOil Atomization
  • Air CompressorNot Included

Dimensions and Weights

  • Overall Length24' 8-1/2"
  • Overall Height11' 3-5/8"
  • Overall Width11' 1"
  • Shipping Weight46,290 LBS
  • Operating Weight74,990 LBS
  • Boiler Outlet8" ø 300# FLG.
  • Exhaust Outlet24" ø OD

Technical Overview PDF

Download PDF